Flexential - Atlanta/Alpharetta (ATL3/4)
Flexential - Atlanta/Alpharetta (ATL3/4) is an operational data center operated by Flexential in Alpharetta, United States. Our footprint estimate of its power is about 9.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Flexential |
| Facility power | 9.7 MW (range 4.8 MW to 16 MW) Estimate from building footprint, low confidence. Footprint estimate: about 8,073 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 2 networks PeeringDB. |
| Also known as | Flexential Atlanta - Alpharetta Data Center |
| Address | 12655 Edison Dr. |
| Coordinates | 34.08716, -84.25235 |
| Website | flexential.com |
Power and grid
| Nearest high-voltage substation | Windward Substation, 230 kV, 1.4 km away (Georgia Power) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 21 |
| Utility | Sawnee Electric Membership Corporation (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SOCO |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 19.5 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.1 GW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 352 g CO₂ per kWh (Georgia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 38.7%, nuclear 34.8%, coal 13.6%, solar 8.1%, bioenergy 3.2%. Clean power: 47.6% |
| Industrial power price | USD 0.131 per kWh (Georgia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 16.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.1 °C (2001 to 2025) |
| Cooling degree days | 1,020 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.43 kWh per m² per day |
| Wind at 50 m | 4.5 m/s average |
| Water stress today | Medium - High (20-40%) (Georgia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Flexential - Atlanta/Alpharetta (ATL3/4) use?
We estimate the facility power at about 9.7 MW. Estimate from building footprint, low confidence.
How close is Flexential - Atlanta/Alpharetta (ATL3/4) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Windward Substation (230 kV), about 1.4 km away. The local utility is Sawnee Electric Membership Corporation, in the SOCO balancing area.
How clean is the power for Flexential - Atlanta/Alpharetta (ATL3/4)?
The grid in Georgia emits about 352 g CO₂ per kWh (2025). Largest sources: gas 38.7%, nuclear 34.8%, coal 13.6%.
Who operates Flexential - Atlanta/Alpharetta (ATL3/4)?
Flexential.
Data centers near Alpharetta
- Secure Data Center 741 m · 34 MW
- Hewlett-Packard 1.5 km · 18 MW
- T5 Data Center 1.7 km · 12 MW
- Mapletree Industrial 1.7 km · 22 MW
- Strategic Datasphere 1.8 km · 41 MW
- 365 Data Centers Alpharetta (GA1) 3.2 km
- Data center in Alpharetta 3.5 km · 2.8 MW
- Ascent - Atlanta Data Center 3.8 km · 7.8 MW
More Flexential data centers
- Douglasville 2 United States
- Flexential - Atlanta/Douglasville (ATL5) United States
- Flexential - Portland/Hillsboro 3 (PDX03) United States
- Flexential - Dallas/Plano (DFW01) United States
- Flexential - Denver/Englewood (DEN11) United States
- Flexential - Portland/Hillsboro 2 (PDX02) United States
- Flexential Dallas - Richardson United States
- Flexential - Portland/Hillsboro 4 (PDX04) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.