IBM Horsham
IBM Horsham is an operational data center operated by IBM in Southwater, United Kingdom. Our footprint estimate of its power is about 9.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | IBM |
| Facility power | 9.4 MW (range 4.7 MW to 15 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,819 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 51.02156, -0.35047 |
Power and grid
| Nearest high-voltage substation | Horsham Grid Substation, 132 kV, 5.1 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Bolney Substation, 400 kV, 9.6 km away |
| HV substations within 10 km | 2 |
| Power plants within 50 km | 884 MW in 69 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 11 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 32.7 °C (2001 to 2025) |
| Cooling degree days | 44 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.94 kWh per m² per day |
| Wind at 50 m | 7.4 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does IBM Horsham use?
We estimate the facility power at about 9.4 MW. Estimate from building footprint, low confidence.
How close is IBM Horsham to the power grid?
The nearest high-voltage substation in OpenStreetMap is Horsham Grid Substation (132 kV), about 5.1 km away.
How clean is the power for IBM Horsham?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Who operates IBM Horsham?
IBM.
Data centers near Southwater
- Digital Realty LGW15 16.9 km · 12 MW
- 4D Gatwick (Crawley) 17.3 km · 1.4 MW
- Restore Records Management 23.6 km · 15 MW
- Goldman Sachs data center in East Grinstead 25.0 km · 11 MW
- Surrey Data Park 25.4 km · 3.3 MW
- Brighton Digital Exchange BTN1 25.8 km
- Unit 2 28.5 km · 3.6 MW
- Navisite Redhill UK 28.5 km · 12 MW
More IBM data centers
- IBM Auckland New Zealand
- Datacenter IBM - Grabels France
- Datacenter IBM France
- Datacenter IBM France
- Datacenter IBM France
- Datacenter IBM France
- Datacenter IBM France
- IBM Gigaplex Switzerland
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.