Data Center Directory

Meta Huntsville Data center

Meta Huntsville Data center is an operational data center operated by Meta in Meridianville, United States. Our footprint estimate of its power is about 106 MW. Likely chips: NVIDIA GPUs (some Meta MTIA) (guess).

Key facts

StatusOperational
OperatorMeta
Facility power106 MW (range 53 MW to 170 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 88,719 m² building outline x 1 floor(s) x 1.2 kW/m².
AI chipsNVIDIA GPUs (some Meta MTIA)
Guess from the operator, not confirmed. Meta trains on NVIDIA GPUs and adds in-house MTIA chips for inference.
GPU capacity if all AIabout 45,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates34.84044, -86.62883

Power and grid

Nearest high-voltage substationFlash Substation, 161 kV, 300 m away (Meta)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationMadison Substation, 500 kV, 10.9 km away
HV substations within 10 km4
UtilityCity Of Huntsville (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityTVA
Nearest gas pipelineSouthern Natural Gas Co, interstate pipeline, 8.3 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km5.6 GW in 8 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity399 g CO₂ per kWh (Alabama, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 45.6%, nuclear 30%, coal 15.2%, hydro 5.8%, bioenergy 2.3%. Clean power: 39.1%
Industrial power priceUSD 0.081 per kWh (Alabama, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature15.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature41.3 °C (2001 to 2025)
Cooling degree days935 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.32 kWh per m² per day
Wind at 50 m4.5 m/s average
Water stress todayLow - Medium (10-20%) (Alabama)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Meta Huntsville Data center use?

We estimate the facility power at about 106 MW. Estimate from building footprint, low confidence.

What chips does Meta Huntsville Data center use?

No chips are reported. Based on the operator, the likely chips are NVIDIA GPUs (some Meta MTIA).

How close is Meta Huntsville Data center to the power grid?

The nearest high-voltage substation in OpenStreetMap is Flash Substation (161 kV), about 300 m away. The local utility is City Of Huntsville, in the TVA balancing area.

How clean is the power for Meta Huntsville Data center?

The grid in Alabama emits about 399 g CO₂ per kWh (2025). Largest sources: gas 45.6%, nuclear 30%, coal 15.2%.

Who operates Meta Huntsville Data center?

Meta.

Data centers near Meridianville

More Meta data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.