Meta Huntsville Data center
Meta Huntsville Data center is an operational data center operated by Meta in Meridianville, United States. Our footprint estimate of its power is about 59 MW. Likely chips: NVIDIA GPUs (some Meta MTIA) (guess).
Key facts
| Status | Operational |
|---|---|
| Operator | Meta |
| Facility power | 59 MW (range 29 MW to 94 MW) Estimate from building footprint, low confidence. Footprint estimate: about 48,970 m² building outline x 1 floor(s) x 1.2 kW/m². |
| AI chips | NVIDIA GPUs (some Meta MTIA) Guess from the operator, not confirmed. Meta trains on NVIDIA GPUs and adds in-house MTIA chips for inference. |
| GPU capacity if all AI | about 25,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 34.84348, -86.62886 |
Power and grid
| Nearest high-voltage substation | Flash Substation, 161 kV, 700 m away (Meta) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Madison Substation, 500 kV, 11.1 km away |
| HV substations within 10 km | 4 |
| Utility | City Of Huntsville (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | TVA |
| Nearest gas pipeline | Southern Natural Gas Co, interstate pipeline, 8.6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.6 GW in 8 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 399 g CO₂ per kWh (Alabama, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.6%, nuclear 30%, coal 15.2%, hydro 5.8%, bioenergy 2.3%. Clean power: 39.1% |
| Industrial power price | USD 0.081 per kWh (Alabama, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 15.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.3 °C (2001 to 2025) |
| Cooling degree days | 935 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.32 kWh per m² per day |
| Wind at 50 m | 4.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Alabama) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Meta Huntsville Data center use?
We estimate the facility power at about 59 MW. Estimate from building footprint, low confidence.
What chips does Meta Huntsville Data center use?
No chips are reported. Based on the operator, the likely chips are NVIDIA GPUs (some Meta MTIA).
How close is Meta Huntsville Data center to the power grid?
The nearest high-voltage substation in OpenStreetMap is Flash Substation (161 kV), about 700 m away. The local utility is City Of Huntsville, in the TVA balancing area.
How clean is the power for Meta Huntsville Data center?
The grid in Alabama emits about 399 g CO₂ per kWh (2025). Largest sources: gas 45.6%, nuclear 30%, coal 15.2%.
Who operates Meta Huntsville Data center?
Meta.
Data centers near Meridianville
- Meta Huntsville Data center 338 m · 106 MW
- Meta Huntsville Data Center 579 m · 344 MW
- Data center in Meridianville 879 m · 48 MW
- Data center in Meridianville 1.7 km · 26 MW
- Meta Huntsville 11.3 km · 198 MW
- Simple Helix 12.3 km · 2.9 MW
- George C. Wallace Alabama Supercomputer Center 12.6 km · 2.6 MW
- DC BLOX HSV1 - DCBLOX Huntsville 15.7 km
More Meta data centers
- Meta Hyperion United States
- QTS Cedar Rapids United States
- Meta Prometheus United States
- Meta Bowling Green United States
- Meta Montgomery United States
- QTS Eagle Mountain United States
- Meta Huntsville Data Center United States
- Altoona Meta Data Center United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.