nLighten Hamburg HAM1
nLighten Hamburg HAM1 is an operational data center operated by nLighten HQ in Hamburg, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | nLighten HQ |
| Networks | 2 networks PeeringDB. |
| Address | Großmoorbogen 25, 21079 Hamburg |
| Coordinates | 53.45372, 10.00583 |
| Website | nlighten.com/en/germany-data-center/hamburg |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 300 m away (Hamburger Energienetze) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 380 kV, 7.5 km away |
| HV substations within 10 km | 23 |
| Power plants within 50 km | 950 MW in 10 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.5 °C (2001 to 2025) |
| Cooling degree days | 70 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.88 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Low (<10%) (Hamburg) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is nLighten Hamburg HAM1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 300 m away.
How clean is the power for nLighten Hamburg HAM1?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates nLighten Hamburg HAM1?
nLighten HQ.
Data centers near Hamburg
- PlusServer DataStore Hamburg 2.9 km
- NorthC Hamburg 10.8 km · 6.8 MW
- n@work Hamburg Grevenweg 10.8 km
- euNetworks Colocation Hamburg 11.0 km · 45 MW
- Portus/IPHH HH3 (Wendenstrasse 251) 11.0 km · 9.7 MW
- Artfiles w408 11.1 km
- n@work Hamburg Wendenstraße 11.1 km
- ITENOS Hamburg (HAM1) 11.4 km
More nLighten HQ data centers
- nLighten Swindon BRS2 United Kingdom
- nLighten Leeds LBA1 United Kingdom
- nLighten Strasbourg SXB1 France
- nLighten Besancon MLH1 France
- nLighten Liverpool LPL1 United Kingdom
- nLighten Paris PAR2 France
- nLighten Sophia Antipolis NCE1 France
- nLighten Paris PAR1 France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.