NTT DOCOMO BUSINESS TK2 - Tokyo
NTT DOCOMO BUSINESS TK2 - Tokyo is an operational data center operated by NTT Global Data Centers in Tokyo, Japan. Our footprint estimate of its power is about 3.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 3.8 MW (range 1.9 MW to 6.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,188 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | NTT TK2 |
| Address | 3-8-2 Minamisuna, Koto-ku |
| Coordinates | 35.67146, 139.83046 |
| Website | ntt.com/en/services/data-center/nexcenter.html |
Power and grid
| Nearest high-voltage substation | 江東変電所, 275 kV, 1.3 km away (東京電力パワーグリッド) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 17 |
| Power plants within 50 km | 35 GW in 40 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 474 g CO₂ per kWh (Japan, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 32.7%, coal 31.8%, solar 10.8%, nuclear 9.2%, hydro 7.2%. Clean power: 33% |
Climate and water
| Average temperature | 15.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 36.7 °C (2001 to 2025) |
| Cooling degree days | 872 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.77 kWh per m² per day |
| Wind at 50 m | 5.9 m/s average |
| Water stress today | Medium - High (20-40%) (Tokyo) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTT DOCOMO BUSINESS TK2 - Tokyo use?
We estimate the facility power at about 3.8 MW. Estimate from building footprint, low confidence.
How close is NTT DOCOMO BUSINESS TK2 - Tokyo to the power grid?
The nearest high-voltage substation in OpenStreetMap is 江東変電所 (275 kV), about 1.3 km away.
How clean is the power for NTT DOCOMO BUSINESS TK2 - Tokyo?
The grid in Japan emits about 474 g CO₂ per kWh (2025). Largest sources: gas 32.7%, coal 31.8%, solar 10.8%.
Who operates NTT DOCOMO BUSINESS TK2 - Tokyo?
NTT Global Data Centers.
Data centers near Tokyo
- NTT DOCOMO BUSINESS TK9 - Tokyo 467 m · 9.3 MW
- Colt Shiohama 1.9 km
- Equinix TY3 - Tokyo 2.9 km · 19 MW
- Broadband Tower - Monzen-nakacho Bldg. 3.4 km
- 株式会社アット東京 data center in Toyosu 3.6 km
- NTT DOCOMO BUSINESS TK3 - Tokyo 4.2 km
- @Tokyo Chuo Center (CC1 & CC2) 4.3 km · 12 MW
- AT TOKYO (CC1/CC2) 4.4 km
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.