Telstra InfraCo - St Leonards Data Centre

Telstra InfraCo - St Leonards Data Centre is an operational data center operated by Telstra in St Leonards, Australia. Our footprint estimate of its power is about 25 MW.

Key facts

StatusOperational
OperatorTelstra
Facility power25 MW (range 12 MW to 39 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 20,492 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 11,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks, 1 internet exchanges
PeeringDB.
Also known asTelstra Data Centre
Address4A Herbert Street
Coordinates-33.81872, 151.19143
Websitetelstrawholesale.com.au/products/data/telstra-infraco-data-centres.html

Power and grid

Nearest high-voltage substationRoyal North Shore Zone Substation, 132 kV, 300 m away (Ausgrid)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationHaymarket Bulk Supply Substation, 330 kV, 7 km away
HV substations within 10 km36
Power plants within 50 km179 MW in 4 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity518 g CO₂ per kWh (Australia, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 42.9%, solar 20.4%, gas 15.5%, wind 13.8%, hydro 4.4%. Clean power: 39.8%

Climate and water

Average temperature18.7 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.9 °C (2001 to 2025)
Cooling degree days673 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.65 kWh per m² per day
Wind at 50 m5.2 m/s average
Water stress todayHigh (40-80%) (New South Wales)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Telstra InfraCo - St Leonards Data Centre use?

We estimate the facility power at about 25 MW. Estimate from building footprint, low confidence.

How close is Telstra InfraCo - St Leonards Data Centre to the power grid?

The nearest high-voltage substation in OpenStreetMap is Royal North Shore Zone Substation (132 kV), about 300 m away.

How clean is the power for Telstra InfraCo - St Leonards Data Centre?

The grid in Australia emits about 518 g CO₂ per kWh (2025). Largest sources: coal 42.9%, solar 20.4%, gas 15.5%.

Who operates Telstra InfraCo - St Leonards Data Centre?

Telstra.

Data centers near St Leonards

More Telstra data centers