CyrusOne SAT10 & SAT11
CyrusOne SAT10 & SAT11 is an operational data center operated by CyrusOne in Lackland Air Force Base, United States. Our footprint estimate of its power is about 12 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | CyrusOne |
| Facility power | 12 MW (range 4.7 MW to 29 MW) Estimate from building footprint, low confidence. Footprint estimate: about 97,509 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 5,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 29.41822, -98.78784 |
Power and grid
| Nearest high-voltage substation | Texas Research Substation, 138 kV, 300 m away (CPS Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Cagnon Road Substation, 345 kV, 6.7 km away |
| HV substations within 10 km | 6 |
| Utility | Bandera Electric Coop, INC (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ERCO |
| Nearest gas pipeline | El Paso Texas Pipeline Co, intrastate pipeline, 5.9 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.2 GW in 23 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 20.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 44.5 °C (2001 to 2025) |
| Cooling degree days | 1,804 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.84 kWh per m² per day |
| Wind at 50 m | 6.1 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does CyrusOne SAT10 & SAT11 use?
We estimate the facility power at about 12 MW. Estimate from building footprint, low confidence.
How close is CyrusOne SAT10 & SAT11 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Texas Research Substation (138 kV), about 300 m away. The local utility is Bandera Electric Coop, INC, in the ERCO balancing area.
How clean is the power for CyrusOne SAT10 & SAT11?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates CyrusOne SAT10 & SAT11?
CyrusOne.
Data centers near Lackland Air Force Base
- Vantage TX1 274 m · 45 MW
- Data center in Lackland Air Force Base 302 m · 21 MW
- Microsoft 1.5 km · 31 MW
- Microsoft Texas Research Park Campus 1.6 km · 87 MW
- Microsoft TRP1 1.6 km · 15 MW
- Microsoft TRP3 (SAT46) 1.9 km · 19 MW
- Data center in Leon Valley 7.9 km · 14 MW
- Data center in Leon Valley 8.1 km · 14 MW
More CyrusOne data centers
- CyrusOne NVA5 United States
- CyrusOne FRA3 Germany
- CyrusOne Sterling United States
- CyrusOne Aurora I United States
- CyrusOne Sterling NVA9 United States
- CyrusOne NVA14 United States
- CyrusOne Lebanon United States
- CyrusOne NC-1 United States