CyrusOne Wappingers Falls
CyrusOne Wappingers Falls is an operational data center operated by CyrusOne in Wappingers Falls, United States. Our footprint estimate of its power is about 9.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | CyrusOne |
| Facility power | 9.4 MW (range 4.7 MW to 15 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,842 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | 155 Myers Corners Road, (f/k/a 165-167 Myers Corner Road) |
| Coordinates | 41.59904, -73.88222 |
| Website | cyrusone.com |
Power and grid
| Utility | Central Hudson Gas & Elec Corp (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | NYIS |
| Nearest gas pipeline | Iroquois Gas Trans Co, interstate pipeline, 15.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 268 g CO₂ per kWh (New York, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.4%, nuclear 20.7%, hydro 18.5%, solar 7.6%, wind 5%. Clean power: 52.9% |
| Industrial power price | USD 0.105 per kWh (New York, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.1 °C (2001 to 2025) |
| Cooling degree days | 424 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.87 kWh per m² per day |
| Wind at 50 m | 4.3 m/s average |
| Water stress today | Low - Medium (10-20%) (New York) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does CyrusOne Wappingers Falls use?
We estimate the facility power at about 9.4 MW. Estimate from building footprint, low confidence.
How clean is the power for CyrusOne Wappingers Falls?
The grid in New York emits about 268 g CO₂ per kWh (2025). Largest sources: gas 45.4%, nuclear 20.7%, hydro 18.5%.
Who operates CyrusOne Wappingers Falls?
CyrusOne.
Data centers near Wappingers Falls
- IBM Quantum Data Center 8.3 km · 10 MW
- Evocative New York (JFK2) 47.7 km
- SD / Comsat Southbury Ground Station 52.0 km
- TierPoint Hawthorne (fka Xand) 57.1 km
- Data center in Orangeburg 61.2 km · 32 MW
- NYSE Data Center 62.2 km · 18 MW
- Databank Orangeburg (LGA3) 62.8 km · 21 MW
- Bloomberg Data Center 63.2 km · 31 MW
More CyrusOne data centers
- CyrusOne NVA5 United States
- CyrusOne FRA3 Germany
- CyrusOne Sterling United States
- CyrusOne Aurora I United States
- CyrusOne Sterling NVA9 United States
- CyrusOne NVA14 United States
- CyrusOne Lebanon United States
- CyrusOne NC-1 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.