Equinix ME4 - Melbourne, Derrimut (formerly Metronode Melbourne 2)
Equinix ME4 - Melbourne, Derrimut (formerly Metronode Melbourne 2) is an operational data center operated by Equinix in Derrimut, Australia. Our footprint estimate of its power is about 8.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 8.3 MW (range 4.2 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,929 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 5 networks, 1 internet exchanges PeeringDB. |
| Also known as | Equinix ME4 |
| Address | 2 Davis Ct |
| Coordinates | -37.78830, 144.78485 |
| Website | equinix.com/locations/australia-colocation/melbourne-data-centers/me4 |
Power and grid
| Nearest high-voltage substation | Deer Park Terminal Station, 220 kV, 4.5 km away (TransGrid) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 4 |
| Power plants within 50 km | 1.6 GW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 518 g CO₂ per kWh (Australia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 42.9%, solar 20.4%, gas 15.5%, wind 13.8%, hydro 4.4%. Clean power: 39.8% |
Climate and water
| Average temperature | 14.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.9 °C (2001 to 2025) |
| Cooling degree days | 279 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.43 kWh per m² per day |
| Wind at 50 m | 6.2 m/s average |
| Water stress today | High (40-80%) (Victoria) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix ME4 - Melbourne, Derrimut (formerly Metronode Melbourne 2) use?
We estimate the facility power at about 8.3 MW. Estimate from building footprint, low confidence.
How close is Equinix ME4 - Melbourne, Derrimut (formerly Metronode Melbourne 2) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Deer Park Terminal Station (220 kV), about 4.5 km away.
How clean is the power for Equinix ME4 - Melbourne, Derrimut (formerly Metronode Melbourne 2)?
The grid in Australia emits about 518 g CO₂ per kWh (2025). Largest sources: coal 42.9%, solar 20.4%, gas 15.5%.
Who operates Equinix ME4 - Melbourne, Derrimut (formerly Metronode Melbourne 2)?
Equinix.
Data centers near Derrimut
- Digital Realty MEL11 - Melbourne 963 m · 3.8 MW
- AirTrunk MEL1 1.7 km · 10 MW
- AirTrunk data center in Derrimut 1.8 km · 15 MW
- Stack Infrastructure MEL01A 4.8 km · 11 MW
- Microsoft MEL11 6.0 km · 19 MW
- CDC Laverton 6.0 km · 9.9 MW
- CDC Melbourne BK1 6.0 km
- CDC Brooklyn Campus 6.1 km · 15 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.