Data Center Directory

NTT Chicago CH3

NTT Chicago CH3 is an operational data center operated by NTT Global Data Centers in Itasca, United States. Our footprint estimate of its power is about 15 MW.

Key facts

StatusOperational
OperatorNTT Global Data Centers
Facility power15 MW (range 7.5 MW to 24 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 12,483 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 6,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asNTT Chicago CH2 · NTT Chicago CH1
AddressEast Pierce Road 235, 60143, Itasca
Coordinates41.98694, -88.00798
Websiteservices.global.ntt/en-us/services-and-products/global-data-centers/global-locations/americas/chicago-ch1-data-center

Power and grid

Nearest high-voltage substationUnnamed substation, 345 kV, 1.3 km away (Commonwealth Edison)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km13
UtilityCommonwealth Edison Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineNatural Gas PL Co of Am, interstate pipeline, 2.5 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km2.7 GW in 31 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.5 °C (2001 to 2025)
Cooling degree days465 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does NTT Chicago CH3 use?

We estimate the facility power at about 15 MW. Estimate from building footprint, low confidence.

How close is NTT Chicago CH3 to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (345 kV), about 1.3 km away. The local utility is Commonwealth Edison Co, in the PJM balancing area.

How clean is the power for NTT Chicago CH3?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates NTT Chicago CH3?

NTT Global Data Centers.

Data centers near Itasca

More NTT Global Data Centers data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.