NTT Chicago CH4

NTT Chicago CH4 is an operational data center operated by NTT Global Data Centers in Itasca, United States. Our footprint estimate of its power is about 9.4 MW.

Key facts

StatusOperational
OperatorNTT Global Data Centers
Facility power9.4 MW (range 4.7 MW to 15 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 7,835 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 4,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressArlington Heights Road 1200, 60143, Itasca
Coordinates41.98910, -88.00476
Websiteservices.global.ntt/en-us/services-and-products/global-data-centers/global-locations/americas/chicago-ch1-data-center

Power and grid

Nearest high-voltage substationUnnamed substation, 345 kV, 1.3 km away (Commonwealth Edison)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km13
UtilityCommonwealth Edison Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineNatural Gas PL Co of Am, interstate pipeline, 2.2 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km2.7 GW in 31 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.5 °C (2001 to 2025)
Cooling degree days465 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does NTT Chicago CH4 use?

We estimate the facility power at about 9.4 MW. Estimate from building footprint, low confidence.

How close is NTT Chicago CH4 to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (345 kV), about 1.3 km away. The local utility is Commonwealth Edison Co, in the PJM balancing area.

How clean is the power for NTT Chicago CH4?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates NTT Chicago CH4?

NTT Global Data Centers.