NTT Hemel Hempstead 1 Data Center (HH1)
NTT Hemel Hempstead 1 Data Center (HH1) is an operational data center operated by NTT Global Data Centers in Hemel Hempstead, United Kingdom. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Networks | 2 networks PeeringDB. |
| Address | 3 Centro, Boundary Way |
| Coordinates | 51.76420, -0.43450 |
| Website | datacenter.hello.global.ntt/location/london/hemel-hempstead-1-data-center |
Power and grid
| Nearest high-voltage substation | Piccotts End Grid, 132 kV, 3.5 km away (UK Power Networks) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Elstree Substation, 400 kV, 13.1 km away |
| HV substations within 10 km | 4 |
| Power plants within 50 km | 3.1 GW in 110 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 10 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.3 °C (2001 to 2025) |
| Cooling degree days | 36 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.88 kWh per m² per day |
| Wind at 50 m | 7.1 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is NTT Hemel Hempstead 1 Data Center (HH1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Piccotts End Grid (132 kV), about 3.5 km away.
How clean is the power for NTT Hemel Hempstead 1 Data Center (HH1)?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Who operates NTT Hemel Hempstead 1 Data Center (HH1)?
NTT Global Data Centers.
Data centers near Hemel Hempstead
- NTT Hemel Hempstead 3 Data Center (HH3) 299 m · 21 MW
- NTT Hemel Hempstead 2 Data Center (HH2) 531 m · 11 MW
- NTT Hemel Hempstead 4 Data Center (HH4) 738 m · 24 MW
- BT Computer Centre 7.9 km · 4 MW
- The Chess Building 13.5 km · 17 MW
- Data center in Dunstable 15.5 km · 8.6 MW
- Elstree Customer Hosting Centre 16.2 km
- ServerChoice SC-2 16.3 km
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.