NTT Slough 2 Data Center (SL2)
NTT Slough 2 Data Center (SL2) is an operational data center operated by NTT Global Data Centers in Slough, United Kingdom. Our footprint estimate of its power is about 4.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 4.6 MW (range 2.3 MW to 7.4 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,855 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 1 networks PeeringDB. |
| Also known as | NTT Slough 3 Data Center (SL3) · NTT Slough 2 · NTT Slough 3 |
| Address | 670 Ajax Avenue |
| Coordinates | 51.51681, -0.61569 |
| Website | datacenter.hello.global.ntt/location/london/slough-2-data-center |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 132 kV, 1 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Iver Substation, 400 kV, 8.7 km away |
| HV substations within 10 km | 12 |
| Power plants within 50 km | 3.8 GW in 96 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.9 °C (2001 to 2025) |
| Cooling degree days | 53 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.94 kWh per m² per day |
| Wind at 50 m | 7.1 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTT Slough 2 Data Center (SL2) use?
We estimate the facility power at about 4.6 MW. Estimate from building footprint, low confidence.
How close is NTT Slough 2 Data Center (SL2) to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (132 kV), about 1 km away.
How clean is the power for NTT Slough 2 Data Center (SL2)?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Who operates NTT Slough 2 Data Center (SL2)?
NTT Global Data Centers.
Data centers near Slough
- Kao Data KLON-06 144 m · 17 MW
- Digital Realty London LHR26 160 m · 9.6 MW
- VIRTUS LONDON9 324 m · 34 MW
- Digital Realty London LHR27 329 m
- Rackspace Slough 441 m · 5.8 MW
- Iron Mountain LON-2 579 m · 12 MW
- Lumen 686 m · 3.6 MW
- VIRTUS London 11 769 m · 7.2 MW
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.