Microsoft DUB03 / DUB04

Microsoft DUB03 / DUB04 is an operational data center operated by Microsoft in Lucan, Ireland. Our footprint estimate of its power is about 65 MW. Likely chips: NVIDIA GPUs (some Microsoft Maia) (guess).

Key facts

StatusOperational
OperatorMicrosoft
Facility power65 MW (range 32 MW to 104 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 53,975 m² building outline x 1 floor(s) x 1.2 kW/m².
AI chipsNVIDIA GPUs (some Microsoft Maia)
Guess from the operator, not confirmed. Microsoft AI capacity is mostly NVIDIA, with a few in-house Maia chips.
GPU capacity if all AIabout 28,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asMicrosoft DUB05
Coordinates53.32483, -6.45426

Power and grid

Nearest high-voltage substationKilmahud 110kV Substation, 110 kV, 100 m away (EirGrid)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationCastlebaggot 220kV Substation, 220 kV, 1 km away
HV substations within 10 km31
Power plants within 50 km3.5 GW in 41 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity261 g CO₂ per kWh (Ireland, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 48.1%, wind 37.8%, solar 4.7%, bioenergy 3.3%, oil and other fossil 2.9%. Clean power: 47.8%
Industrial power priceEUR 0.206 per kWh (Ireland, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature24.3 °C (2001 to 2025)
Cooling degree days1 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.74 kWh per m² per day
Wind at 50 m8 m/s average
Water stress todayLow (<10%) (Ireland)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low (<10%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Microsoft DUB03 / DUB04 use?

We estimate the facility power at about 65 MW. Estimate from building footprint, low confidence.

What chips does Microsoft DUB03 / DUB04 use?

No chips are reported. Based on the operator, the likely chips are NVIDIA GPUs (some Microsoft Maia).

How close is Microsoft DUB03 / DUB04 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Kilmahud 110kV Substation (110 kV), about 100 m away.

How clean is the power for Microsoft DUB03 / DUB04?

The grid in Ireland emits about 261 g CO₂ per kWh (2025). Largest sources: gas 48.1%, wind 37.8%, solar 4.7%.

Who operates Microsoft DUB03 / DUB04?

Microsoft.