NTT Ashburn Campus
NTT Ashburn Campus is an operational data center operated by NTT Global Data Centers in Ashburn, United States. Its power is about 21 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 21 MW Derived from a tagged IT power value. IT power tag in OpenStreetMap |
| IT power | 16 MW |
| GPU capacity if all AI | about 8,900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | NTT VA3 · NTT VA7 · NTT VA4 · NTT VA5 · NTT VA6 |
| Opened | 2018 |
| Coordinates | 39.01796, -77.47192 |
| Website | nttdata.com/en-us/services/global-data-centers/global-locations/americas/northern-virginia-data-centers/ashburn-va-3-data-center |
Power and grid
| Utility | Virginia Electric & Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | PJM |
| Nearest gas pipeline | Columbia Gas Trans Co, interstate pipeline, 3.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 729 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.98 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTT Ashburn Campus use?
Public data puts the facility power at about 21 MW. Derived from a tagged IT power value.
How clean is the power for NTT Ashburn Campus?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Who operates NTT Ashburn Campus?
NTT Global Data Centers.
Data centers near Ashburn
- RagingWire VA3 - NTT 184 m
- NTT VA8 326 m · 16 MW
- Aligned Ashburn (IAD-01) 479 m
- Aligned IAD-01 498 m · 78 MW
- Digital Realty IAD (21625 Gresham) 542 m · 44 MW
- Sabey Intergate.Ashburn 620 m · 30 MW
- Digital Realty IAD (21745 Sir Timothy) 633 m · 38 MW
- Data center in Ashburn 664 m · 4.9 MW
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom