Centersquare Boston (BOS4-A)
Centersquare Boston (BOS4-A) is an operational data center operated by Centersquare in Watertown, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Centersquare |
| Networks | 2 networks PeeringDB. |
| Address | 486 Arsenal Way |
| Coordinates | 42.36577, -71.15808 |
| Website | centersquaredc.com/data-centers/boston |
Power and grid
| Nearest high-voltage substation | Electric Avenue Substation, 115 kV, 1 km away (Eversource) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | North Cambridge Substation, 345 kV, 3.1 km away |
| HV substations within 10 km | 24 |
| Utility | Massachusetts Bay Trans Authority (political subdivision) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ISNE |
| Nearest gas pipeline | Algonquin Gas Trans Co, interstate pipeline, 2.9 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.3 GW in 157 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 403 g CO₂ per kWh (Massachusetts, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 65.4%, solar 24.6%, oil and other fossil 4.5%, bioenergy 3.2%, hydro 1.4%. Clean power: 30.1% |
| Industrial power price | USD 0.200 per kWh (Massachusetts, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38 °C (2001 to 2025) |
| Cooling degree days | 356 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.82 kWh per m² per day |
| Wind at 50 m | 4.7 m/s average |
| Water stress today | Low - Medium (10-20%) (Massachusetts) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Centersquare Boston (BOS4-A) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Electric Avenue Substation (115 kV), about 1 km away. The local utility is Massachusetts Bay Trans Authority, in the ISNE balancing area.
How clean is the power for Centersquare Boston (BOS4-A)?
The grid in Massachusetts emits about 403 g CO₂ per kWh (2025). Largest sources: gas 65.4%, solar 24.6%, oil and other fossil 4.5%.
Who operates Centersquare Boston (BOS4-A)?
Centersquare.
Data centers near Watertown
- Lumen Boston 5.9 km
- Hub Express System 6.4 km
- Evocative BOS1 6.5 km
- CoreSite - Boston (BO1) 6.5 km · 12 MW
- Expedient Boston 8.1 km
- Markley Group One Summer Street Boston 8.1 km
- Cogent Boston 8.6 km
- 230 Congress 8.6 km
More Centersquare data centers
- Centersquare Dallas (DFW1) United States
- Centersquare Chicago (ORD2) United States
- Centersquare Atlanta (ATL1-A/B/C) United States
- Centersquare Chicago (ORD4) United States
- Centersquare Northern Virginia (IAD4) United States
- Centersquare New Jersey (EWR5) United States
- Centersquare Northern Virginia (IAD1-C/E) United States
- Centersquare Seattle (SEA1-B) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.