Stonewall Creek Business Park

Stonewall Creek Business Park is an operational data center operated by Google in Leesburg, United States. Our footprint estimate of its power is about 15 MW. Likely chips: Google TPU (plus NVIDIA GPUs for cloud customers) (guess).

Key facts

StatusOperational
OperatorGoogle
Facility power15 MW (range 6.1 MW to 38 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 126,243 m² site outline x 0.12 kW per m² of land.
AI chipsGoogle TPU (plus NVIDIA GPUs for cloud customers)
Guess from the operator, not confirmed. Google runs most of its AI work on its own TPU chips.
GPU capacity if all AIabout 6,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asGoogle Leesburg Building 1
AddressRed Triangle Lane 42300, Leesburg
Coordinates39.05147, -77.53944

Power and grid

Nearest high-voltage substationGant Substation, 230 kV, 300 m away (NOVEC)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km36
UtilityNorthern Virginia Elec Coop (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineDominion Transmission Co, interstate pipeline, 1.1 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km1.6 GW in 29 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity357 g CO₂ per kWh (Virginia, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39%
Industrial power priceUSD 0.100 per kWh (Virginia, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.7 °C (2001 to 2025)
Cooling degree days729 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.98 kWh per m² per day
Wind at 50 m5.3 m/s average
Water stress todayMedium - High (20-40%) (Virginia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Stonewall Creek Business Park use?

We estimate the facility power at about 15 MW. Estimate from building footprint, low confidence.

What chips does Stonewall Creek Business Park use?

No chips are reported. Based on the operator, the likely chips are Google TPU (plus NVIDIA GPUs for cloud customers).

How close is Stonewall Creek Business Park to the power grid?

The nearest high-voltage substation in OpenStreetMap is Gant Substation (230 kV), about 300 m away. The local utility is Northern Virginia Elec Coop, in the PJM balancing area.

How clean is the power for Stonewall Creek Business Park?

The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.

Who operates Stonewall Creek Business Park?

Google.