Data Center Directory

Vantage Data Centers (QC1)

Vantage Data Centers (QC1) is an operational data center operated by Vantage Data Centers in Montreal, Canada. Our footprint estimate of its power is about 7.9 MW.

Key facts

StatusOperational
OperatorVantage Data Centers
Facility power7.9 MW (range 3.9 MW to 13 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 6,564 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,400 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks13 networks, 1 internet exchanges
PeeringDB.
Also known asVantage Data Centers Montreal I
Address2900 Avenue Marie Curie
Coordinates45.48646, -73.75540
Websitevantage-dc.com

Power and grid

Nearest high-voltage substationPoste de Saraguay, 315 kV, 2.2 km away (Hydro-Québec)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km11
Power plants within 50 km2.9 GW in 8 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity192 g CO₂ per kWh (Canada, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 52.8%, gas 19.7%, nuclear 12.8%, wind 8%, coal 2.7%. Clean power: 76.5%

Climate and water

Average temperature6.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature36.6 °C (2001 to 2025)
Cooling degree days272 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.54 kWh per m² per day
Wind at 50 m6.2 m/s average
Water stress todayLow - Medium (10-20%) (Canada)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Vantage Data Centers (QC1) use?

We estimate the facility power at about 7.9 MW. Estimate from building footprint, low confidence.

How close is Vantage Data Centers (QC1) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Poste de Saraguay (315 kV), about 2.2 km away.

How clean is the power for Vantage Data Centers (QC1)?

The grid in Canada emits about 192 g CO₂ per kWh (2025). Largest sources: hydro 52.8%, gas 19.7%, nuclear 12.8%.

Who operates Vantage Data Centers (QC1)?

Vantage Data Centers.

Data centers near Montreal

More Vantage Data Centers data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.