Vantage Data Centers (QC4)

Vantage Data Centers (QC4) is an operational data center operated by Vantage Data Centers in Pointe-Claire, Canada. Our footprint estimate of its power is about 8.3 MW.

Key facts

StatusOperational
OperatorVantage Data Centers
Facility power8.3 MW (range 3.3 MW to 21 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 68,872 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 3,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks17 networks, 1 internet exchanges
PeeringDB.
Also known asHive Data Center - Montreal · DNSnetworks IDC2 · Vantage Montreal II
Address2800 Route Transcanadienne
Coordinates45.47507, -73.80085
Websitevantage-dc.com

Power and grid

Nearest high-voltage substationPoste des Sources, 315 kV, 1.5 km away (Hydro-Québec)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km7
Power plants within 50 km2.9 GW in 8 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity192 g CO₂ per kWh (Canada, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 52.8%, gas 19.7%, nuclear 12.8%, wind 8%, coal 2.7%. Clean power: 76.5%

Climate and water

Average temperature6.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature36.6 °C (2001 to 2025)
Cooling degree days272 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.54 kWh per m² per day
Wind at 50 m6.2 m/s average
Water stress todayLow - Medium (10-20%) (Canada)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Vantage Data Centers (QC4) use?

We estimate the facility power at about 8.3 MW. Estimate from building footprint, low confidence.

How close is Vantage Data Centers (QC4) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Poste des Sources (315 kV), about 1.5 km away.

How clean is the power for Vantage Data Centers (QC4)?

The grid in Canada emits about 192 g CO₂ per kWh (2025). Largest sources: hydro 52.8%, gas 19.7%, nuclear 12.8%.

Who operates Vantage Data Centers (QC4)?

Vantage Data Centers.

Data centers near Pointe-Claire

More Vantage Data Centers data centers